Description of Work:
8/6/2025 1:06:47 PM
SCOPE OF WORK:
- TRENCHED & TRENCHLESS SEWER LATERAL REPLACEMENT VIA PIPE BURSTING FROM TWO FOUNDATION EXITS TO DISTRICT MAIN TIE IN LOCATED ON LOCUST AVE.
- INSTALL SEWER LATERAL WITH 4" AND 6" WITH SDR 17 HDPE PIPE UP TO APPROXIMATELY 265 LF
- INSTALLATION OF (TWO) ONE-WAY CLEANOUTS EQUIPPED WITH SEWER POPPER ENCLOSED IN B9 CHRISTY BOX WITH GRATED LID AT FOUNDATION EXIT
- NEW 6 IN X 6 IN CONNECTION AT MAIN
- POTHOLING REQUIRED IN 6 LOCATIONS FOR UTILITIES LINES
- BACKFILL AND COMPACT EXCAVATED AREAS
- DEMOLITION AND DISPOSAL OF SOIL AND ASPHALT FROM STREET
- DEMOLITION AND DISPOSAL OF CONCRETE
- RESTORATION OF CONCRETE
- RESTORATION OF ASPHALT
11/3/2025 2:50:29 PM
Delta 1: Revision to include tie-in for sewer lateral connection to 1301/1303 Bridgeway, in front of 1309 Bridgeway in sidewalk.